DE  |  EN
Imprint | Contact | Sitemap | Print | Search
Relay card R4103
The R4103 is an 8 channel, 40 A relay card with integrated parallel current measurement for all channels.
The card provides 8 inputs for the DUT (Device-Under-Test). Those can be connected to HC1-8 (HC – High Current Bus) or switched to the 8 outputs of the card for an external load box.
Furthermore, any channel of the DUT , single or parallel, can be connected with a power supply (HC9 and HC10) or with an electronic load (HC11 and HC12).

The integrated 8 channel current measurement module has an accuracy of 0.2% with a resolution of 5 mA. 1 A is the smallest current measurable.

The card must be calibrated every 12 month.
Product number:R4103000
Communication:DLL, LabVIEW VI, VeriStand Custom Device,
MFTS - Manual Operator Software
Bus:Xdbus 2.0
Inputs:8 x 100 mA to 40 A
Outputs:8 x 100 mA to 40 A and HC1-8
Display:Status LED
Relais:12 V
Channels:8
Other:Current measurement sampling rate per channel: 10 S/s
Integrated digital filter
Format:Long double euroboard (233,4 mm x 220 mm), 6U/4HP